Thermal bridging, insulation voids and air leakage on facades and elevations, reported on a balance-of-probability basis with every finding cross-referenced against RGB.
THERMAL + RGBEvery finding in every report follows the same structure — location, frame reference, affected area, confidence, probable cause and recommended action, rated Red / Amber / Green. Here's a worked (illustrative) example from this survey type.
| Location | South elevation, first-floor balcony threshold, units 4–6 |
| Frame reference | 0012_T / 0012_RGB |
| Estimated affected area | Approx. 6 linear metres along the threshold |
| Confidence | Moderate |
| Severity rating (RAG) | AMBER |
Observation: A cool linear thermal signature runs along the balcony threshold, consistent across two passes at different times of day, distinct from the surrounding wall temperature.
Probable cause: On balance of probability, consistent with a structural cold bridge at the balcony-to-floor slab junction, where continuous insulation has likely been interrupted.
Recommended action: Recommend a fabric specialist review the junction detail; consider remedial insulation at next planned works.
Every finding on every survey type is rated against the same published definitions, so a Red on one job means the same thing as a Red on the next.